Jasco Preparative HPLC
Preparative HPLC-systems for separation on 2.1- 5 cm columns
The LC-4000 Series preparative modules for separation from mg to g scale.
Integrated Preparative HPLC Systems
Suitable for sample clean-up from mg to g scale. The LC-4000 Preparative HPLC comes with a large column oven for multiple preparative columns and optional automatic column switching, open-bed fraction collector with sample trays for tubes, plates or large containers and ChromNAV-FC for fraction control using time, threshold or slope from up to 4 different signals.
- ● Up to 120 ml/min
- ● Each system component is completely stackable into a modest height
- ● The system is fully integrated with complete system monitoring
- ● All user replaceable components are accessible through the front panel
- ● Vertical leak/drain system to channel away solvent
- ● Peak collection by time or peak reqognition
- ● All detectors include 100 Hz acquistion with interchangeable flowcells
Product Specialist
Mats Grapne
08-473 33 40
-
Advances in Solvent Delivery
For more than three decades JASCO analytical HPLC pumps have employed an asymmetric twin-piston solvent delivery system SSQD (Slow Suction, Quick Delivery) which provides significantly better flow and pressure profiles than other conventional twin-piston reciprocating designs. Slow-Suction Quick-Delivery (SSQD) has been re-developed, with a completely new solvent delivery mechanism ExReFT (Extremely Reliable Flow Technology) offering the highest stability ‘compensated’ solvent delivery used in the PU-4180/85 RHPLC pump models. -
Pioneering Optical Design
As a pioneer in optical spectroscopy, JASCO has optical designs that few can match. We have developed a range of HPLC detectors with unrivaled performance, like the class leading FP-4020 fluorescence detector (water Raman S/N > 2300:1), RI-4035 UHPLC refractive index detector and the unique CD-4095 circular dichroism detector for chiral chromatography. -
Compact and Easy to Use
The footprint of the LC-4000 Series HPLC is only 30cm – requiring only a very small amount of bench space. For easy maintenance, all LC-4000 instruments feature front-panel access for replacing consumables such as pump components and light sources. The autosampler consumables such as the syringe parts are easy to access. -
Front Panel Control
For users requiring front-panel control, the LC-4000 Series retains a keypad and backlit LED display. Keypad control can still be configured for convenient override when under PC control.
Preparative HPLC Pumps
Flow Rate: Up to 20 mL/min
Operating Pressure: Up to 500 Bar
Degassing: Vacuum (Option)
Solvents: 2, 6 or 10
Flow Rate: Up to 50 mL/min
Operating Pressure: Up to 500 Bar
Degassing: Vacuum (Option)
Solvents: 2, 6 or 10
Flow Rate: Up to 120 mL/min
Operating Pressure: Up to 400 Bar
Degassing: Vacuum (Option)
Solvents: 2, 6 or 10
-
Configuration
The unique expansion bays in the pump base can be fitted with plug-in modules to quickly transform a simple isocratic pumping system into a multi-solvent delivery system. Install a second pump (with dynamic mixer) for binary gradients or a quaternary low pressure mixing gradient unit (four solvent), either can be configured with an optional low volume vacuum degasser. A 6 – or 10 solvent selection valve can be added for method development.
-
Control
The PU-4000 Series pumps are normally used as part of a complete HPLC system, however for applications that require stand-alone operation, each instrument has its own keypad and can be controlled using an RS232 protocol and/or contact closures (TTL) to start and stop the pump.
Retention Time Reproducibility
Isocratic Retention time Reproducibility – PU-4180
Isocratic retention time reproducibility and flow accuracy- PU-4180 /1 ml/min)
Conditions
| Mobile Phase | Acetonitrile/Water (80:20) |
| Flow Rate | 1.0mL/min |
| Column | CrestPak C18S (4.6mml.D. x 150mm, 5µm) |
| Column Temperature | 40° C |
| Detection Wave Length | 260nm, Response; 1sec |
| Sample | Polycyclic aromatic hydrocarbon (10µg/mL each) (Naphthalene, Fluorene, Anthracene, Pyrene, Chrysene, Benzon[a]pyrene) |
| Injection | 10 µL |