Jasco LC-4000 series HPLC Pumps


Robust pump solutions from UHPLC to preparative clean-up in gram scale

The LC-4000 Series HPLC pumps have 3 operating pressures RHPLC – rapid (700bar), UHPLC – ultra high performance (1300 bar) and preparative (500 bar). Each base has two expansion bays that allow an isocratic pump to be transformed into a powerful gradient solvent delivery system with optional solvent selection for method development.

HPLC Pumps

Jasco LC-4000 series HPLC Pumps

Jasco LC-4000 series HPLC Pumps

Jasco LC-4000 series HPLC Pumps
HPLC, RHPLC PU-4180, Analytical Pump

RHPLC Pumps

Options: Isocratic, Binary (two pumps and high pressure mixer) and  Quaternary (four solvent gradient mixer with degasser)
Flow Rate: Up to 5 mL/min gradient (10mL/min isocratic)
Operating Pressure: Up to 700 Bar
Degassing: Vacuum (Option)
Solvents: 2, 6 or 10
Jasco LC-4000 series HPLC Pumps
RHPLC, PU-4185 Semi-Micro Pump

RHPLC Semi- Micro Pumps

Options: Isocratic, (two pumps and high pressure mixer)
Flow Rate: Up to 4 mL/min
Operating Pressure: Up to 700 Bar
Degassing: Vacuum (Option)
Solvents: 2, 6 or 10
Jasco LC-4000 series HPLC Pumps
UHPLC, PU-4285 Semi-Micro Pump

UHPLC Pumps

Options: Isocratic, Binary (two pumps and high pressure mixer)
Flow Rate: Up to 2 mL/min gradient (10mL/min isocratic)
Operating Pressure: Up to 1,300 Bar
Degassing: Vacuum (Option)
Solvents: 2, 6 or 10
Jasco LC-4000 series HPLC Pumps
PREPARATIVE, PU-4086/87/88 preparative pumps

Preparative Pumps

Options: Isocratic, (two pumps and high pressure mixer)
Flow Rate: Up to 20 mL/min (PU-4086)
Flow Rate: Up to 50 mL/min (PU-4087)
Flow Rate: Up to 150 mL/min (PU-4088)
Operating Pressure: Up to 500 Bar
Degassing: Vacuum (Option)
Solvents: 2, 6 or 10
  • Configuration

    The unique expansion bays in the pump base can be fitted with plug-in modules to quickly transform a simple isocratic pumping system into a multi-solvent delivery system. Install a second pump (with dynamic mixer) for binary gradients or a quaternary low pressure mixing gradient unit (four solvent), either can be configured with an optional low volume vacuum degasser.  A 6 – or 10 solvent selection valve can be added for method development.
  • Control

    The PU-4000 Series pumps are normally used as part of a complete HPLC system, however for applications that require stand-alone operation, each instrument has its own keypad and can be controlled using an RS232 protocol and/or contact closures (TTL) to start and stop the pump.

Retention Time Reproducibility

Isocratic Retention time Reproducibility – PU-4180

Isocratic Retention time Reproducibility

Isocratic retention time reproducibility and flow accuracy- PU-4180 /1 ml/min)

Conditions

Mobile Phase  Acetonitrile/Water (80:20) 
Flow Rate  1.0mL/min
Column  CrestPak C18S (4.6mml.D. x 150mm, 5µm)
Column Temperature  40° C
Detection Wave Length  260nm, Response; 1sec
Sample  Polycyclic aromatic hydrocarbon (10µg/mL each)
(Naphthalene, Fluorene, Anthracene, Pyrene, Chrysene, Benzon[a]pyrene)
Injection  10 µL