Skip to main content

Setaflash Series 8 Flash Point Tester


Petroleum and Fuel Analysis

Closed cup flash point tester provides fast and reliable flash point results

The Setaflash Series 8 High Temperature, closed cup flash point tester provides fast and reliable flash point results with a wide temperature range of 5 to 300 °C.

System Description

With the Series 8, a test takes less than 2 minutes with just a 2 or 4 ml sample size. A simple user interface with colour digital display and touchscreen icons guides you through the straightforward testing process. For easy record keeping the instrument stores 100,000 test results which can be saved and transferred via a USB port.

Designed for precise and accurate tests, barometric pressure is measured by an internal barometer and correction is automatically applied to the test result. Unknown samples can be tested using ramp mode.

Setaflash Series 8 can also be purchased with ActiveCool and Corrosion Resisting Cup.

  • ● Simple test procedure

  • ● Compact, rugged design

  • ● Gas ignition

  • ● Automated flash detection

  • ● Ramp mode for unknown samples

  • ● Automatic barometric pressure correction

  • ● Fire detection (alarm and relay)

  • ● USB port and result storage

Product Specialist

Mikael Alfredsson Kovalent

Mikael Alfredsson

"Our expert in Digestion, Extraction, Syntesis and Evaporation with more than 20 years experience in the field of sales and service. Contact me for if you have questions or need a quotation"

Additional Information

Ease of use:
All functions on the Series 8 including test parameters, instrument status and test results are accessed via the touchscreen display. An audible prompt sounds when a flash is achieved and an automatic flash detector enhances repeatability.

Safety:
The instrument incorporates an over-temperature cutout that cuts the power to the heater if the cup temperature exceeds 320 °C. A fire sensor immediately stops the test and cools the sample cup if a fire is detected.

Calibration and verification:
Calibration of the Series 8 can be performed in the field, eliminating the costs and time associated with sending the instrument to a service centre.

Service and maintenance:
The rugged design ensures minimal operational maintenance is needed.

Supplied with: 2 ml syringe, 99878-3 CRM, Allen keys, mains lead and instruction manual.

Industries

  • ● Automotive

  • ● Aviation

  • ● Biodiesel

  • ● Chemicals & Solvents

  • ● Cosmetis & Fragrances

  • ● Crude Oil

  • ● Energy & Power

  • ● Lubricants

  • ● Marine

  • ● Paint,Varnish & Waxes

  • ● Petroleum - Fuels & Oils

  • ● Pharmaceuticals

  • ● Printing Inks

  • ● Transportation,Storage & Packaging

  • ● Waste & Envisromental

Methods

  • ● ASTM D1655

  • ● ASTM D3278

  • ● ASTM D3828

  • ● ASTM D7236

  • ● ASTM D8174

  • ● ASTM E502

  • ● IP 523

  • ● IP 534

  • ● BS EN ISO 3679 & BS 2000-523

  • ● CLP REGULATIONS EC NO 1272/2008

  • ● ISO 3679

  • ● ISO 3680 (OBS)